Description
Capacity
200 Lt, 300 Lt,500 Lt, 650 Lt, 850 Lt, 1000 Lt, 1250 Lt, 1500 Lt, 2000 Lt
Construction
-AISI 304 quality stainless steel
-1st wall base is 2 mm and it also has 0,8 mm Ep type laser welded cooler evaporator surface that is coupled to wall.
-1 st wall body 1,5 mm
-Isolated body 1 mm
-Cooler unit and tank body are mounted on single chassis.
-There are 1, 25 W 21 d/d redactor and stainless steel mixer blade on redactor.
-Isolation range has 50 mm thickness, isolated with water based, non-HCFC high density polyurethane foam material.
-Product output has DN50 male sleeve, butterfly valve.
-There is also spring cover.
-There is Ø 200 mm covered product entry on the cover.
-There is manual measuring scale with ‰ 3-4 sensitivity rate.
-There are adjustable bolted stands under the tank.
-Design that allow zero liquid to remain in the rank during discharge.
-Welded sections are welded with 1 st class Argon TIG welding and has 1 st class smooth polishing.
Cooling Group
-Fast Cooling without crystallization within minimum milk volume
-Minimum gas charging
-Cooling with R404 A gas
-Kromel Milk Cooling Tanks provide each milking to cool from 35 °C to 4 °C at ambient temperature (32 °C - 38 °C)
-Direct Expansion System
-TSE 13732/CE/EAC regulation of Compliance certificate
-Test of Compliance Certificate
-Optionally, design Suitable for 2, 4 and 6 milking time
Electric Group
-Protection grade IP 65 Electric control panel
-200 Lt, 300 Lt, 500 Lt, 650 Lt, 850 Lt, and 1000 Lt tanks operate at 220 volt energy and 850 Lt and above operate at 380 Volt energy.
-Digital thermometer heat level indicator
-Electronic control card that is specially designed and is able to control the milk temperature and operation of the tank, easy utilization
-Phase protection relay
-System disables automatically when the cover of the tank is opened.
-Automatic mixing program with special software; Mixer operation time may be adjusted with desired intervals after the milk is brought to desired ser value. (3 minutes of operation, 10 minutes of break)
Washing System
-Manual washing
Option
-Emergency cooling switch, digital level indicator
-Digital weighbridge can be added
Capacity
A
(L)
B
(H)
C (Ø)
(W)
D
(H)
Weight
200 L
1400
1150
800
1400
120
300 L
1630
1350
930
1600
160
500 L
1800
1290
1075
1660
175
650 L
1800
1450
1075
1750
200
850 L
2100
1300
1380
1730
230
1000 L
2100
1450
1380
1900
250
1250 L
2450
1300
1690
1850
320
1500 L
2450
1450
1690
2000
345
2000 L
2700
1450
1950
2020
395